For cardiac markers and therapeutic drugs.
Have you successfully revived a dead Integra 400+? Tell us your war story in the comments below.
Clean the sample/reagent probe exterior using lint-free gauze and 70% isopropyl alcohol.
The service manual is more than just a repair guide; it is a comprehensive blueprint for the instrument's longevity. Accessing official documentation via the Roche eLabDoc portal ensures you have the latest specifications for: Service Manual Cobas Integra 400 Plus
The Integra uses air pressure to mix reagents and wash the probes. The service manual includes a flow chart that seems confusing until you realize all paths lead to the . If your probes are dripping liquid (error: Liquid level detection failed), the manual’s troubleshooting tree will lead you to check the liquid trap (Part 115). Clean that before you replace any expensive valves.
The Cobas Integra 400 Plus service and technical documentation covers essential maintenance, configuration, and troubleshooting for the clinical chemistry analyzer, with detailed procedures often reserved for certified technicians. Available resources include user manuals, SOPs for routine operations, and host manuals for LIS integration. For comprehensive technical specifications, maintenance, and troubleshooting, refer to resources provided by Roche and technical documentation platforms. UserManual PDF - Scribd
Execute the automated daily wake-up and rinse protocols using system wash solutions. For cardiac markers and therapeutic drugs
Inspect the reaction cuvettes for scratches, smudges, or optical degradation. Replace standard segments if errors occur during blanking.
A Training Manual is available for support personnel, detailing system configuration and . Troubleshooting & Maintenance :
The Cobas Integra 400 Plus requires regular calibration and quality control checks to ensure accurate and reliable test results. The service manual provides guidelines for: The service manual includes a flow chart that
: Shut down the instrument, unplug the power source, and open the main cover. Cleaning Materials 0.6% sodium hypochlorite solution , 70% ethanol, and reagent-grade Type 1 water. Safety & Training
| Interval | Action | Key Parts (from manual) | | :--- | :--- | :--- | | Weekly | Clean probes & wash stations | N/A (operator task) | | Monthly | Replace cuvette segments (if degraded) | Cuvette segment (P/N 03151146001) | | Quarterly | Replace peristaltic pump tubing | Pump tubing set (P/N 03214325001) | | Annually | Full mechanical calibration & lamp change | Halogen lamp (P/N 03097921001) |