Select the : Choose PULSE for momentary actions (like a 5-second bell ring) or ON/OFF for continuous actions (like switching on security lights). Set the trigger time (Hour and Minute). If you chose a Pulse event, define the Duration in seconds. Select the Days of the week the event should execute. Press ENTER to confirm and save the program block. 🔧 Troubleshooting Common ECAT Punto 4 Issues Probable Cause Corrective Action Blank LCD Screen Main power failure or blown fuse.
If the ECAT Punto 4 encounters operational issues, use this matrix to diagnose and resolve common faults. Potential Cause Faulty power supply or incorrect wiring polarity.
: Carefully tilt the faceplate forward. Be mindful of the delicate ribbon cable connecting the keypad board to the primary power supply board underneath. On the back of the keypad board, you will spot a cylindrical, typically blue accumulator (backup battery).
module box - Ecat Orologi
To safely commission the master clock, use the following manual procedure: ecat punto 4 manual pdf
: Turn the detached front panel over. The internal safety accumulator is a distinct, blue cylindrical module located on the upper-left corner. Just below and slightly to the right is the matching jumper bridge connector.
Use the arrow keys to adjust the current , Month , and Day . Press ENTER after each entry. Adjust the Hour and Minute .
: Managing relay settings and external sensors, such as GPS for self-correcting time.
Flip the loose panel over to find the blue cylindrical battery pack secured on the upper left-hand side. Select the : Choose PULSE for momentary actions
The Punto 4 belongs to a series of master clocks (including models like SP1, DODICI, and VENTI) with the following capabilities:
The back terminal of the Punto 4 handles time-distribution outputs, inputs for synchronization receivers, and system power lines. Wire the device according to this terminal pinout map: Terminal Label / Function Connection Requirement Neutral 230 VAC & Phase 230 VAC Time Distribution Output 3-wire 220 VAC distribution (Common, Return 1, Return 2) Impulse Output 12/24 VCC (+ / -) for polarized slave clocks Relay Channel 1 Normally Open (NO), Common (COM), Normally Closed (NC) Relay Channel 2 Normally Open (NO), Common (COM), Normally Closed (NC) Relay Channel 3 Normally Open (NO), Common (COM), Normally Closed (NC) Relay Channel 4 Normally Open (NO), Common (COM), Normally Closed (NC) Synchro Outputs OUT ECAT Code 1 & GND0 ECAT Code 2 Radio Receiver Inputs +12V (Red), Code In (Yellow), GND (Black/Shield) Menu Architecture and Programming
While continuing to hold the keys, turn the power supply back on.
Capacità di gestione fino a 44 canali (4 uscite interne + 40 esterne) con 2 comandi indipendenti per orologi secondari. Ecat Orologi P R O D U C T S C A T A L O G U E | P R O D U I T S Select the Days of the week the event should execute
To ensure you have the most up-to-date information, it is highly recommended to download the manual directly from the manufacturer’s official support website or authorized distributors. Visit the official manufacturer website. Go to the "Support" or "Downloads" section.
wiring (including relay outputs for bell hammers and synchronization) can be found on platforms like Yumpu .
: Allows you to program a service (like a bell chime) between two dates and on specific weekdays.