Drager Pulsar 7000 Manual

Wide range of hydrocarbons (Alkanes methane to hexane, propylene) Operating Range Three distinct models: 4–60 m, 30–120 m, or 100–200 m Output Signal 4 to 20 mA (analogue), digital link, and HART® 7 Housing Material Stainless steel AISI 316L "Marine Grade" Environmental negative 40 raised to the composed with power C positive 60 raised to the composed with power C negative 40 raised to the composed with power F positive 140 raised to the composed with power F Safety Integrity SIL 2 certified by TÜV Nord (EN 61508) Diagnostics & Maintenance

4 to 20 mA analog interface alongside digital HART® communication.

Connect the to power and your control system/PLC using the 4–20 mA or HART loops. drager pulsar 7000 manual

Fix the alignment brackets to the structure using stainless steel hardware. Electrical Wiring

What (Short, Medium, Long) you are working with? Wide range of hydrocarbons (Alkanes methane to hexane,

Optics require cleaning; system is still operating but accuracy may degrade. Normal Operation Clean air baseline; 0 LEL.m detected. Gas Detection

Initial rough alignment is done by eye, followed by fine adjustment using spring-loaded screws and a handheld terminal. No additional telescopes or mirrors are typically required. Electrical Wiring What (Short, Medium, Long) you are

The system requires an intrinsically safe connection to the ⁠Dräger Pulsar Interface Adapter (PIA) . The PIA is a robust, hazardous-area certified accessory that enables communication for calibration. 3. Calibration and Maintenance (According to the Manual)

| Problem / Fault | Possible Causes (as per manual) | Required Action (as per manual) | | :--- | :--- | :--- | | | Incorrect power supply | Establish correct power supply | | "Beam Block" or "Error" indication | Measuring path blocked between Tx and Rx Lenses of the Tx or Rx are dirty Tx and Rx not correctly aligned Tx and Rx set to different channels | Clear the measuring path Clean the lenses Align the Tx and Rx Set the same channel on both units | | No 4-20 mA signal | 4-20 mA cable connected incorrectly Pulsar Interface Adapter batteries empty | Check the 4-20 mA cable Replace batteries in the adapter | | Zero calibration unsuccessful | Gas present in the measuring path during compensation Lenses are dirty Tx and Rx incorrectly aligned | Ensure no gas is in the path during calibration Clean the lenses Align the Tx and Rx | | No communication via connection port | Communication connection is faulty Connector not fully inserted | Send device to Dräger Service Establish correct connection |

Connect the to a power supply (Typically 18–30 V DC).