Opti Combi Manual English - Prosecure
The is more than a dry technical document—it’s the key to making your security system work for you, not against you. Whether you’re a DIY enthusiast or a certified installer, take an hour to read through the programming and troubleshooting sections.
The sensor features several physical and digital adjustment options to customize the detection field. prosecure opti combi
The ProSecure Opti Combi features an 8-wire harness. Wire colors must match the corresponding terminals on your automatic door controller. Pin Number Wire Color Description Power Supply 12-24 V AC / 12-30 V DC (Non-polarized) 2 Power Supply 12-24 V AC / 12-30 V DC (Non-polarized) 3 Activation Output Motion Relay - Connects to Inner/Outer Activation 4 Activation Output Motion Relay - Connects to Inner/Outer Activation 5 Safety Output Presence Relay - Connects to Safety/Presence Input 6 Safety Output Presence Relay - Connects to Safety/Presence Input 7 Test Input Monitoring loop connection to door controller 8 Test Input Monitoring loop connection to door controller prosecure opti combi manual english
If your door controller requires a monitored safety loop (EN 16005 compliance), connect the remaining auxiliary wires (often Blue/Red or designated on the board terminals) to the test output of the door control unit. Adjust the sensor's internal DIP switches to match the test signal logic (Active High or Active Low). 4. Mechanical Adjustments: Field Geometry
Turn the sensitivity potentiometer clockwise to expand the zone size or counterclockwise to reduce it. The is more than a dry technical document—it’s
Microwave (Doppler radar) for detection + Active Infrared (AIR) for safety. Compliance: Designed to meet EN 16005 standards.
The sensor operates in a state of high sensitivity, with the active infrared field maintaining a constant, safe zone in front of the door. The microwave radar detects approaching users, initiating the opening cycle. 4.2 Maintenance prosecure opti combi The ProSecure Opti Combi features
Mount the sensor centered above the door opening.
Use the mechanical click-wheel adjustment to move the safety curtain closer to or further away from the door blades.
| Code | Meaning | User Action | |------|---------|--------------| | E101 | Column motor timeout | Power cycle; check travel path | | E204 | Laser misalignment | Run calibration routine (service only) | | E311 | Sensor not detected (intraoral) | Re-plug cable; restart SW | | E450 | High voltage ripple >10% | Call service technician |
Adjust internal clips or lenses to change the field from wide-and-shallow to narrow-and-deep. Infrared Field Adjustments (Safety Presence)